Difference between revisions of "Planning"
From Tranzman Documentation
(→Clients) |
(→Server) |
||
Line 29: | Line 29: | ||
* OUTBOUND - to the Tranzman Appliance TCP 111,4045 and 2049 and UDP 111,4045 and 2049 (Only on *nix Destination servers). | * OUTBOUND - to the Tranzman Appliance TCP 111,4045 and 2049 and UDP 111,4045 and 2049 (Only on *nix Destination servers). | ||
− | ==Server== | + | ==Tranzman Appliance (Server)== |
− | * INBOUND - TCP | + | * INBOUND - TCP 55001-55555 from clients |
* INBOUND - TCP 443 from ANY | * INBOUND - TCP 443 from ANY | ||
* INBOUND - TCP 22 from ANY | * INBOUND - TCP 22 from ANY | ||
* INBOUND - TCP 80 from ANY | * INBOUND - TCP 80 from ANY | ||
− | * INBOUND - TCP 139 and 445 and UDP 137 and 138 from | + | * INBOUND - TCP 139 and 445 and UDP 137 and 138 from destination Windows servers. |
− | * INBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 from | + | * INBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 from destination *nix servers. |
− | * OUTBOUND - TCP 139 and 445 and UDP 137 and 138 to | + | * OUTBOUND - TCP 139 and 445 and UDP 137 and 138 to destination Windows servers |
− | * OUTBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 to | + | * OUTBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 to destination Unix servers. |
+ | * INBOUND - TCP 139 and 445 and UDP 137 and 138 from Administration PC(s) Windows Only. | ||
+ | * OUTBOUND - TCP 139 and 445 and UDP 137 and 138 to Administration PC(s) Windows Only. | ||
===Storage=== | ===Storage=== |
Revision as of 07:57, 5 February 2019
To help determine the correct sizing for a Tranzman Appliance, it is recommended that the Tranzman Recorder is used to help better understand the current environment.
A single Tranzman Appliance can be used to convert many environments, the following considerations need to be taken into account when sizing it.
RAM
- Minimum of 2GB of RAM (when If using appliance only for assessments)
- Minimum of 4GB of RAM (when migrating Same Vendor)
- Minimum of 8GB of RAM (when migrating Cross Vendor)
- Additional 1GB of RAM is required for every tape drive connected to the Appliance.
CPU
- Minimum 2 core Intel CPU is required (for Same Vendor or Assessment).
- Minimum 4 core Intel CPU is required (for Cross Vendor).
- Additional 1 core for every tape drive connected to the Appliance.
- ONLY INTEL processors have been tested and are supported.
Network
- 1Gbit minimum connection required (for Same Vendor migration and recovery on Demand).
- 10Gbit connection recommended for Cross Vendor to ensure that tape drive are kept running at a reasonable speed.
- If multiple links are used, aggregation is needed to provide maximum throughput.
- Multiple connections may be required if there are multiple tape drives.
Network Ports
Backup Servers (Clients or Tranzman)
- OUTBOUND - to Tranzman Appliance TCP 55001-55555
- INBOUND - TCP 139 and 445 and UDP 137 and 138 from the Tranzman Appliance (only on Windows Destination servers).
- INBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 from the Tranzman Appliance (only on *nix Destination servers).
- OUTBOUND - to the Tranzman Appliance TCP 139 and 445 and UDP 137 and 138 (only on Windows Destination Servers).
- OUTBOUND - to the Tranzman Appliance TCP 111,4045 and 2049 and UDP 111,4045 and 2049 (Only on *nix Destination servers).
Tranzman Appliance (Server)
- INBOUND - TCP 55001-55555 from clients
- INBOUND - TCP 443 from ANY
- INBOUND - TCP 22 from ANY
- INBOUND - TCP 80 from ANY
- INBOUND - TCP 139 and 445 and UDP 137 and 138 from destination Windows servers.
- INBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 from destination *nix servers.
- OUTBOUND - TCP 139 and 445 and UDP 137 and 138 to destination Windows servers
- OUTBOUND - TCP 111,4045 and 2049 and UDP 111,4045 and 2049 to destination Unix servers.
- INBOUND - TCP 139 and 445 and UDP 137 and 138 from Administration PC(s) Windows Only.
- OUTBOUND - TCP 139 and 445 and UDP 137 and 138 to Administration PC(s) Windows Only.
Storage
- Minimum 3GB local disk for OS Installation.
- Local/SAN attached disks needed for temporary staging of converted images, sized according to volume of recoveries to accommodate at any one time.
Assessment Only
- Additional disk of Minimum 20GB
Same Vendor
- Additional disk(s) of Minimum ((2.5 X Size of combined catalogs) + (2 X Total Memory))
Cross Vendor
- Additional disk(s) of Minimum ((2.5 X Size of combined catalogs) + (2 X Total Memory) + Largest of either
- 3 x Largest image size
- Number of Drives X max size of compressed tape